Type 1 lightning current arresters must be provided at the entrance point into the building for all outdoor lighting systems in lpz 0 a. Kurn lightning protection system diciptakan atas dasar pengembangan franklin rod melalui riset yang panjang dan akurat. L1 loss of human life, l2 loss of service to the public, l3 loss of cultural heritage, l4 loss of economical value including service and loss of activity, are introduced with the various sources of damages, i. All substations should be adequately protected against lightning events. Anti petir penangkal petir lightning protection kurn r150rp 2. A lightning rod us, aus or lightning conductor is a metal rod mounted on a structure and intended to protect the structure from a lightning strike. As was stated many times in the past, the conventional lightning protection philosophy, the methods and their. The art and science of lightning protection pdf free download.
Physical damage to structures and life hazard software for design and calculation of lightning protection systems when designing lightning protection systems, various parameters must be taken into account. Reference this document for information on how to protect video equipment from direct lightning strikes. How can we download or view the pdf file using lightning component from documents in salesforce1 app, is it possible to do or not, if yes please suggest how can i achieve this. Protection untuk mendapatkan ha sil cipta yang benarbenar dapat dihandalkan. Design calculations of lightning protection systems part. To reduce susceptibility to induced noise and to limit the degradation of picture quality, twist the. This lightning protection study was done based on the protection of equipment in the.
There is no perfect solution for lightning protection. These trees will have varying degrees of damage ranging from complete shattering and destruction of the tree, to a slow lingering death, to virtually no apparent. Lightning protection the following information is from the. Penangkal petir kur menciptakan elektron bebas diawan yang besor sebogoi early streamer emission ese pada bagion puncok penongkol petir. Generate pdf so far, we have successfully brought lightning components inmemory data to visualforce page control, where the page control is further bound to apex controllers property. All thunderstorms produce lightning and are very dangerous. Sparkta makes it possible to reduce the final cost of the lightning protection system compared to the designs made by using the rolling sphere method.
A properly installed lightning system can safeguard and prevent damage up to 98%. The author examines the physical behavior of lightning, various types of lightning damage, the role of lightning detection and warning in effective protection, as well as options for deflecting or eliminating lightning. This is achieved through a combination of elements such as feeder overhead earth wires, surge diverters, lightning spires, lightning shield wires and the earthing system these combine to form the lightning protection system. Joe lanzoni has over 18 years of experience in the lightning protection, electrical grounding and surge protection industries. Once the need for lightning protection has been established, loss of life and property can be avoided by the installation of an approved lightning protection system. With lightning pdf professional 7, you dont need source files to fix typos, remove text and reformat paragraphs. The basis of conventional lightning protection technology.
Prevectron system details national lightning protection. Facts about lightning a strike can average 100 million volts of electricity current of up to 100,000 amperes can generate 54,000 o f lightning strikes somewhere on the. Pemosongon minimum 3 meter diotos level tertinggi dari obyek yang okon dilindungi. Each year thousands of properties are destructed and damaged globally by lightning strikes. A free pdf reader, adobe acrobat, may be downloaded from the adobe web site. In order to design an effective lightning protection system with franklin rods or capturing meshes, the following rules shall apply. The dehnsupport toolbox software offers a variety of calculation options in the field of lightning protection ranging from risk management to the calculation of the length of the airtermination rods, separation distances and length of the earth electrodes. The researchers in 9 estimate the arising overvoltages due to lightning discharges and evaluate the actual need of lightning protection measures on the basis of the results of the risk analysis. Pdf lightning protection guide 3rd updated edition. Bs eniec 62305 lightning protection general standard. Thousands of trees are struck by lightning every year. Pdf is2309 lightning protection code free download pdf. Product update new strikerisk software for lightning. Details are available in autocad and adobe acrobat formats.
General principles since it is impossible to avoid a lightning strike, the application of lightning protection measures must be considered. A reference guide 1 of 4 lightning protection reference guide polemounted dome cameras in open areas can be susceptible to lightning strikes. Now, the last part is to actually invoke the pdf generation logic. Facts about lightning a strike can average 100 million volts of electricity current of up to 100,000 amperes can generate 54,000 o f lightning strikes somewhere on the earth every second kills 100 us residents per year. At discount low voltage, we offer a wide selection of highquality lightningprotected. Spd, protection of equipment in existing structures. Bonded lightning protections pdf document downloads. With the excel table provided for download, the catch rod length or the guard. The file size of the latest downloadable setup file is 30 mb. Our white papers provide a range of practical examples on lightning and surge.
The following lightning protection study, with its associated drawings, is intended to display the level of protection and suggested lightning protection that should be added to the new ring bus substation configuration in the scope of the umkc substation project. It uses a statistical based simulation model to assess vulnerability of an installation and performance of the shielding system. The catalogue also covers essential technical and specification data, plus a key introduction to the new lightning standards bs en 62305. Lightning is a bright flash of electricity produced by a thunderstorm. Simply put, a structural lightning protection system cannot and will not protect electronic systems from lightning currents and transient overvoltages, thats why we advocate a total solution to earthing and lightning protection. Lightning pdf professional free version download for pc. It is vital to protect telephones and delicate electronic equipment from the catastrophic damage that lightning strikes and power surges can cause. Detail drawings of supporting masts, down conductors, ground systems, and bonding applications for the prevectron 4 electronically activated streamer emission ease lightning protection system. Lab notes lightning protection part 1 qst october 1994, pp. For a finite period, bs eniec 62305 and bs 6651 ran in parallel, but as of august 2008, bs 6651 has been withdrawn and now bs eniec 63205 is the. To determine the need for protection against lightning for a given building structure, the variables to the right are to be considered. The following lightning protection specifications are available for download as pdf files or word documents. History of the station shows many down times before the lightning protection systems installed, with none now. He has conducted numerous site inspections of industrial and commercial facilities, for the purposes of evaluating lightning protection, grounding and surge protection systems.
Its a great conductor of electricity, so do not take a shower, wash your hands, wash dishes or do laundry. Knowing lightning and surge protection terminology, abbreviations, signs and symbols, knowing what is lightning and types of lightning flashes, knowing what is the lightning protection systems lps, types and components, knowing the correct choice of lightning protection system components. The lightning protection of photovoltaic installations is of great importance, in order to warrant the uninterrupted operation of the system and avoid faults and damages of the equipment. If lightning hits the structure, it will preferentially strike the rod and be conducted to ground through a wire, instead of passing through the structure, where it could start a fire or cause electrocution. Standard for the installation of lightning protection systems. All pdf files created are 100% industrystandard and fully compatible with any pdf viewer. In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to know and speak the laws that govern them. Lightning protected 66 punch down blocks, 110 blocks. Lightning protection system lps earthing design services.
Dari keseluruhan data data penelitian yang didapat dan dipelajari ulang, maka dari hasil tersebut disempurnakan dengan sebaik baiknya untuk mendapatkan hasil cipta yang benar benar dapat dihandalkan. We request the entire layout and digital formatting of the inside pages of your book be saved as a pdf file with all fonts and images embedded and saved at a 300 dpi resolution. Easy pdf file guidelines for book printing by lightning press. Now, we need to create a visualforce page to generate the actual pdf and invoke this page. We provide information about lightning strikes, lightning hazards, related equipment, sources of lightning protection system installers, and lightning strike risk assessment we also provide a master index to this topic, or you can try the page top or bottom search box as a quick way to find information you need. Lightning protection system lps earthing design services liberty consulting services lcs uses the industry leading software package cdegs current distribution, electromagnetic fields, grounding and soil structure analysis, to model lightning induced earth potential rise and. Kurn r 150 kurn r 85 2,7 kg 24 kg 31nchi 3 inchi 150 m 85 m. Specification kurn lightning terminal k urn terminal merupakan ala t penangkal petir yang d i design untuk menciptakan med an ion is asi pada sekeliling area lonezer dissipation system. Kesempurnaan hasil cipta itu send iri dibagi dalam 2 dua bagian, yaitu.
Download free cad detail of a lightning protection air terminal to be used in your architectural construction cad drawings. Lightning protection is a requirement, as well as a smart move, for contractors and building owners or users. The art and science of lightning protection a lightning strike to an unprotected object or system can be disastrous i. In article design calculations of lightning protection systems part two, i indicated the lightning protection design process involves a number of design steps as in fig. Periodic inspection of earthing and shortcircuiting devices. Lightning protection standard the bs eniec 62305 standard for lightning protection was originally published in september 2006, to supercede the previous standard, bs 6651. Do not use electric equipment like computers and appliances during a storm. The authors would like to thank the following people in alphabetic. If you hear the sound of thunder, then you are in danger from lightning. Lightning damage in the us alone cost over 5 billiondollars annually. Planning software for lightning protection systems. Jul 27, 2017 generate pdf so far, we have successfully brought lightning components inmemory data to visualforce page control, where the page control is further bound to apex controllers property. Lightning pdf professional 7 is the complete pdf alternative to adobe acrobat specifically designed for business users. Description download is2309 lightning protection code free in pdf format.